Watch the quick video below to learn how to calibrate the kiosk!
Before You Begin
Check for missing or blocked cams within Manager Mode > Advanced > Calibration and Cams.
💡 Please see Missing / Stuck Cam Alert and Cam Possibly Blocked Alert for more details
Required Items
- Calibration Board
- Need a new calibration board? Either print out this PDF and attach it to a thick piece of cardboard or reach out to Mashgin Support for a new board
- Item 3-4 inches tall
- Item 5-8 inches tall
Calibrate
- First pose should be of the base completely empty
- Tip: Press Pose to add new poses
- Add 7-10 poses of the calibration board flat on the base in different positions
- Add 7-10 poses of the calibration board elevated on top of an item that is 3-4 inches tall in different positions
- Add 7-10 poses of the calibration board elevated on top of an item that is 5-8 inches tall in different positions
- Add 7-10 poses of the calibration board angled at a low angle in different positions
- Add 7-10 poses of the calibration board angled at a steep angle in different positions
- Remove all items from base
- Press Calibrate
Successful Calibration | Unsuccessful Calibration |
✋🏽 For any additional questions, please contact our support team at help@mashgin.com